BX Series

BXM

type

Flameproof Ex d ˙ Increased safety Ex e ˙ For indoor & outdoor applications

For Unarmoured cables
foto BXM type BX series rcn
BXM-esploso-21

Cable glands BXM type 
(code: BXM)

The cable glands of the BXM series have been designed for the use with a conduit with a threaded end, or to a fl exible conduit with the use of an intermediate fi ttings. It has a body which holds the container intended to contain the epoxy resin for sealing the cables.
Above the container is positioned an intermediate and body whose upper part has been specially threaded to be coupled with a conduit tube with a threaded end or to a fl exible conduit with the use of an intermediate fi ttings. A backnut that is going to be screwed onto the body of the cable gland serves to block in position the intermediate body and container.

Application fields

Surface - Group II ˙ Mines - Group I

Approvals / Certifications

ATEX certifi cate: CESI 14ATEX069X
IEC Ex certifi cate: IECEx CES 15.0001X
UKCA certifi cate: CML 21UKEX1594X
EAC certifi cate: HACTXOЛ RU C-IT.AЯ45.B.00909
CCC Ex NEPSI certifi cate: Nr. 2021322313003704

Protection type

Ex db IIC • Ex eb II (gas) • Ex tb IIIC (dusts) • Ex db I • Ex eb I (mines)

EPL (Equipment protection level)

Zone 1-2: Mb mines • Gb, Gc gas
Zone 21-22: Db Dc combustible dusts

Execution

Ex db IIC • Ex eb II • Ex tb IIIC • Ex db I • Ex eb I Db according to
ATEX: EN IEC 60079-0:2018 • EN 60079-1:2014 •
EN IEC 60079-7:2015/A1:2018 • EN 60079-31:2014 • EN 60529:1991
IEC Ex: IEC 60079-0:2017 • IEC 60079-1:2014 •
IEC 60079-7:2015/A1:2017 • IEC 60079-31:2013
IEC 60529:1989+A1:1999+A2:2013

Ambient temperatures range:

-60°C ÷ +110°C

Service temperatures range:

-60°C ÷ +130°C

Cable type

Unarmoured

Available materials

Brass (code: OT) • Nickel-plated brass (code: ON)
AISI316L Stainless steel (code: S6) • Aluminium (code: AL)

Available threads

ISO 262 Metrical • ISO 228 • DIN 40430 Pg
ANSI B1.20.1 NPT • EN 10226 Gk (only for ATEX)

Degree of protection

The cable glands degree of protection is IP66 or IP66/68, 30-meters depth for 7 days according to the IEC EN 60529 standard; the degree of protection IP 68 is obtained by using fl at sealing rings on cable glands with cylindrical threads. Without gaskets, the degree
of protection is IP 66. If the cable glands with cylindrical or tapered threads are screwed on the threaded hole of an apparatus, in order to guarantee an IP66 or IP66/68 degree of protection, threaded parts must be sealed with Loctite or similar. In order to maintain the IPX8 degree of protection, the cable entry shall be fi tted on enclosure witch satisfi es an immersion test under 30 meters of water during 7 days. Metric cable glands are made in accordance to
EN 62444 Standard.

BXN-BXA-BXC-BXM-resina-21

DESIGNED FOR SEALING ONE OR MORE CORES

Example Code

example code BXM type table or
example code type table ot on sa al

Technical Drawing

BXM-disegno-21
BXM type table details